Critical infrastructure · Power and backup
UPS, battery banks, automatic transfer and power quality—designed with real redundancy and maintained with Schneider Electric authorized service.
We design, install and maintain uninterruptible power systems for data centers and critical rooms: Schneider Electric and APC UPS in redundant configurations, battery banks, maintenance bypass and automatic transfer to generation. The goal is that the critical load never loses power—neither during a grid outage nor during maintenance.
In a critical room, power is the leading cause of downtime. A grid outage, a disturbance or an unmaintained UPS can stop servers, communications and entire processes. That is why the backup system is designed as a whole: UPS, batteries, switchboards, transfer and generation must work in coordination.
We work with Uptime Institute Tier criteria: we aim to remove single points of failure and enable concurrent maintainability—servicing any piece of equipment without dropping the load.
We run audits with network analyzers—measuring harmonics, flicker, imbalance and transients—and deliver a report with actions to protect equipment and reduce losses. It is the recommended starting point before expanding or renewing a backup system.
We rent Schneider Electric and APC UPS units for construction, events, migrations or while a unit is being repaired: we install, monitor and remove them when you are done. To renew equipment, PowerPlus gives you access to Schneider Electric’s official Exchange program at preferential prices.
From design to operation
Power, runtime and redundancy calculations based on the critical load and its projection.
Genuine Schneider Electric and APC equipment with factory warranty.
Assembly, wiring, load tests and system documentation.
UPS and battery alarms and trends integrated into the DCIM platform.
Preventive, corrective and predictive maintenance with genuine parts.
Network analyzer measurements and a corrective action report.
Case studies
Frequently asked questions
Can’t find your question?
In N+1 there is one module or unit beyond what the load needs: if one fails, the rest carry it. In 2N there are two complete, independent systems, each able to supply the full load, which also allows maintaining an entire system without affecting operation.
We recommend scheduled preventive maintenance following the manufacturer’s plan and battery condition, complemented by continuous monitoring to anticipate battery, fan and capacitor failures.
Yes, when the system has a maintenance bypass or redundancy. If your installation doesn’t allow it, the assessment tells you what changes are needed.
Yes. As a Schneider Electric Authorized Services Reseller we provide authorized service for existing Schneider and APC equipment, with genuine parts.